엘리먼트 Grade | S | P/PD | H | U | C |
---|---|---|---|---|---|
잔류 입자 크기 (ISO 12500-3) | 3.0㎛ | 1.0㎛ | 0.01㎛ | 0.01㎛ | 0.01㎛ |
고형 입자 제거 효율 (ISO 12500-3) | - | 99.999+% | 99.999+% | 99.999+% | 99.999+% |
유분 제거 효율 (ISO 12500-1) | 50% | 80% | 99.9+% | 99.99+% | - |
잔류 유분 (ISO 12500-2) | 5.0mgf㎥ | 2.0mgf㎥ | <0.01mgf㎥ | <0.001mgf㎥ | <0.004mgf㎥ |
Model | 처리유량 | 접속구경 | 외형치수(mm) | 중량 | |
---|---|---|---|---|---|
N㎥/min | PT | W | H | kg | |
S/P/H/U/C70, P70D | 1.98 | 1/2" | 114 | 260 | 0.9 |
S/P/H/U/C150, P150D | 4.25 | 3/4" | 132 | 271 | 1.4 |
S/P/H/U/C200, P200D | 5.66 | 1" | 132 | 335 | 1.6 |
S/P/H/U/C300, P300D | 8.49 | 1 1/2" | 200 | 346 | 3.8 |
S/P/H/U/C500, P500D | 14.14 | 2" | 200 | 575 | 5.3 |
S/P/H/U/C800, P800D | 22.65 | 3" | 231 | 852 | 8.5 |
S/P/H/U/C1100, P1100D | 31.15 | 3" | 231 | 1034 | 12.6 |
S/P/H/U/C1600, P1600D | 45.30 | 3" | 231 | 1302 | 18.7 |
입구압력(bar) | 2.0 | 2.9 | 3.9 | 4.9 | 5.9 | 6.9 | 7.8 | 8.8 | 9.8 | 10.8 | 11.8 | 12.7 | 13.7 | 14.7 | 15.7 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
보정계수 | 0.40 | 0.50 | 0.62 | 0.75 | 0.87 | 1.00 | 1.11 | 1.22 | 1.34 | 1.47 | 1.58 | 1.71 | 1.83 | 1.95 | 2.07 |
엘리먼트 Grade | Filter Description | 설치위치 |
---|---|---|
S | 세퍼레이터 / 필터 | 1. 애프터쿨러 후단 2. 애프터쿨러 또는 세퍼레이터가 설치되지 않은 경우 |
P/PD | 일반적인 불순물 여과 필터 / 흡착식 후단 전용 | 1. 고효율 유분제거 필터 전단 2. 세퍼레이터 / 필터 후단 3. 흡착식 드라이어 후단 4. 냉동식 드라이어 전단 |
H | 유분제거 필터 | 1. 흡착식 드라이어 전단 2. 냉동식 드라이어 후단 3. 전단에 세퍼레이터 / 필터가 설치 된 경우 |
U | 고효율 유분제거 필터 | 1. 흡착식 드라이어 전단 2. 멤브레인 드라이어 전단 3. 냉동식 드라이어 후단 |
C | 증기상태의 유분 및 냄새제거필터 | 1. 유분기 제거 필터 후단 2. 고효율 유분제거 필터 후단 |